Contact Us

F156

Built-in type weighing indicator for CC-Link

Product Outline

F156 is a weighing controller that can be directly connected to Mitsubishi Electric’s general-purpose sequencer. It allows the weighing system construction time to be reduced with serviceability improved. Equipped with the weighing sequence function, which allows direct control of feeding and discharging gates only by entering the target weight value, F156 of compact design is ideal for use integrated into a control panel, etc. Its integration into equipment and installation of DIN rail are also supported.

Specifications

Analog section
Excitation voltage 10V DC ±5%, Output current; within 120mA,
Remote sense type (Up to 4 loadcells at 350Ω are parallel-connectable.)
Zero adjustment range 0 to approx. 2mV/V
Gain adjustment range 0.3 to 2.0mV/V
Min. input sensitivity 0.3μV/count
Accuracy Non-linearity: within 0.01% FS
Zero drift: within 0.1μV/°C RTI (Typ: 0.08μV/°C)
Gain drift: within 15ppm/°C (Typ: 7ppm/°C)
Analog filter Bessel low-pass filter (-12dB/oct.)
selectable from 2, 4, 6, 8 Hz
A/D converter Speed: 500 times/sec.
Resolution: 16bit
Min. display resolution 1/10000 (Internally 1/40000)
Setting section
Setting method Setting by host on CC-Link or RS-232C interface, or setting by separately-sold remote console unit C110 or C120
Setting value storage ・ Initial setting values: NOV RAM (nonvolatile RAM)
・ Other setting values: C-MOS RAM with backup of a lithium battery
* In either case above, rewrite can be locked.
Setting items ・ Final, SP1, Before final, FF, over, under, high limit, Low limit, near zero, tare set
・ Compare inhibit time, judging time, complete output time, CPS feed time, auto zero times, judging times, FF CPS coefficient, average count of FF CPS, FF CPS
・ Select final and over/under comparison, select HI/LO limit comparison, select near zero comparison, discharge control mode, digital tare subtraction ON/OFF, FF CPS ON/OFF, complete signal output mode, over/under comparison mode, HI/LO limit comparison mode
・ Digital filter, motion detect (period), motion detect (range), zero tracking (period), zero tracking (range), analog filter, count of console display, SI/F gross/net select
・ Balance weight, capacity, min. scale division, net over, gross over, DZ regulation, decimal place, gravitational acceleration, set value LOCK (SOFT LOCK)
・ Simple comparison, select sequence mode, sequence mode CPS feed ON/OFF, sequence mode near zero check ON/OFF, sequence mode weight check ON/OFF, select external control input 0 – 4, select external control output 0 to 6
・ tare, tare reset, digital zero, digital zero reset, sequence start/stop, sequence error reset, zero calibration, span calibration
External signal ・ Input/output (14p amphenol type connector)
・ Input (5 points): ON when shorted to COM terminal
・ Output (7 points): Transistor’s open collector output; ON when transistor’s ON. Vceo=30V (max), Ic=50mA (max)
Interface
CC-Link Field network to link with Mitsubishi’s PLC
Transmission medium: 3-wire type (with shield)
Transmission rate: Selectable from 156k/ 625k/ 2.5M/ 5M/ 10M bps
RS-232C Write / read weight data, various statuses and setting values via commands from host computer (Exclusive use with setting remote console unit, C110 or C120)
Specification: RS-232C conformance, Transmission mode: Full duplex, asynchronous
Transfer rate: 1200/ 2400/ 4800/ 9600/ 19200/ 38400 bps
Format: Data length: 7/8 bit
Stop bit length: 1/2 bit
Parity bit: Odd/ even/ none
SI/F 2-wire type serial interface. This is an interface to connect to Unipulse printers, external display units, etc. Transmission mode: Asynchronous, Transfer rate: 600 bps
General performance
Power supply voltage 100 to 240V AC (+10% -15%) (Free power supply 50/60Hz)
Power consumption 13.0/12.5VA (Rating: 100V)
Operating conditions Temperature: Working temperature range -10°C to +40°C;
Storage temperature range -20 to +80°C
Humidity: 85% RH or less (non-condensing)
Dimensions 67(W)×185(H)×130(D) mm (protruding parts not included)
Weight Approx. 1.7kg
Attachments
AC input cable (3m) 1
Spare fuse (0.5A) 1
Loadcell input connector 1
57 series 14p connector for external I/O 1
RS-232C connector 1
CC-Link connector 1
Terminal block connection driver 1
Wall anchor 1
Crimping terminal 3
Operation manual 1

Optional accessories

Model
C110 Setting remote console unit, 4 keys, Cable length 0.5m
C120 Setting remote console unit, 12 keys, Cable length 0.5m
CAAC2P-B3 AC input cord 3m
CAAC3P-CEE7/7-B2 AC input cord (withstand voltage: 250V) 2m
CA38X11 Mini DIN-D-Sub 25p crossing cable 1m
CN20 57 series 14p connector for external I/O
CN60 Round DIN 8p connector for RS-232C
CN71 CC-Link connector
CA4131 (6-core) cable with JR connector at one end (cable end is separated) 3m
CA4230 JR-PRC conversion relay (6-core) cable 0.3m
CA4311 JR-PRC conversion relay (6-core) 4-wire type / 6-wire type (for 520A) 1m

C120(left)/C110(right)

Download

Product catalogue(PDF)
F156 Product catalogue Dowmload
Operation manual(PDF)
External dimention
DXF
(ZIP)
PDF
Support tools
Software
  • User registration is required to download operation manuals, external dimentions, support tools and software .
  • Acrobat Reader software from Adobe Systems is required to view PDF files.