F158
Weighing indicator for OMRON SYSMAC CJ1/CJ2/NJ
Product Outline
F158 is a weighing controller that allows direct connection to the base module of OMRON’s general-purpose sequencer SYSMAC α. Since inter-equipment wiring is not required, weighing system construction time can be reduced with serviceability improved. With the power supply shared, drastic cost reductions can be achieved.
Specifications
Analog section|Display section|Setting section|General performance|Attachments
Analog section | |
Terminal block input | [+EXC, +S, -S, -EXC, +SIG, -SIG] 6-wire type (Ratiometric method) |
---|---|
Excitation voltage | 5V DC ±5%, Output current; within 60mA, Ratiometric method (Up to 4 loadcells at 350Ω are parallel-connectable.) |
Input range | 0.0 to 2.2mV/V |
Zero adjustment range | [Initial dead load] 0 to 2.0mV/V |
Gain adjustment range | 0.3 to 2.0mV/V |
Min. input sensitivity | 0.15μV/count |
Accuracy |
Non-linearity: within 0.01% FS Zero drift: within 0.25μV/°C RTI Gain drift: within 15 ppm/°C |
Analog filter | Bessel low-pass filter (-12dB/oct.), Cutoff frequency; 2Hz |
A/D converter | Speed: 100 times/sec. Resolution: 16bit |
Min. display resolution | 1/10000 |
Display section | |
Display unit | Front panel LED |
---|---|
Status display | ・ RUN: Lights when the unit is initialized. ・ CAL: Lights when a calibration error occurs and flashes when it is being calibrated. ・ OVR: Lights when the weight alarm status is ON. ・ CMD: Lights when a setting error occurs. |
Setting section | |
Back setting DIP switch |
・ 1: MD0[MODE0] ・ 2: MD1[MODE1] ・ 3: MD2[MODE2] ・ 4: MD3[MODE3] ・ 5: RSV[RESERVE] ・ 6: RSV[RESERVE] ・ 7: RSV[RESERVE] ・ 8: LK[LOCK](Calibration is prohibited when ON) Combination of MD0 to MD3 determines operation mode. |
---|---|
M/C No. rotary switch | High performance I/O unit M/C No. setting |
Setting values | ・ Calibration, setting method: Setting from setting remote console unit (C110, C120) or PLC. ・ Setting value storage: NOV RAM (Nonvolatile RAM) ・ Setting value protection: Setting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction (LOCK). |
Setting items | ・ Setting commands [Setting values not stored] High limit, Low limit, near zero, Final, SP1, Before final, FF, tare reset, over, under [Setting values stored by NOV. RAM] Digital filter, motion detect, zero tracking, balance weight, capacity, min. scale division, digital zero reg., gravitational acceleration compensation, net over, gross over, comparison inhibit time, Judging time, complete output time, decimal place, setting value LOCK, display frequency, FF CPS coefficient, average count of FF CPS, FF regulation, select final/under comparison mode, select HI/LO limit comparison mode, select near zero comparison, discharge control mode, select tare setting, AFC ON/OFF, complete signal output mode, over/under comparison mode ・ Operation commands Zero calibration (registration of initial dead load), span calibration (registration of tilt), tare subtraction, tare reset, digital zero, digital zero reset ・ C110 and C120 allows monitoring of gross weight, net weight and tare weight, change and registration of setting commands, and execution of all operation commands. |
General performance | |
Power consumption | Approx. 400mA when 4 loadcells at 350Ω are connected (with a setting remote console unit connected) |
---|---|
Operating conditions | Temperature: Working temperature range 0 to +40°C; Storage temperature range -20 to +75°C Humidity: 10 to 85% RH (non-condensing) |
Ddimensions | 34.5(W)×130(H)×101(D) mm (protruding parts not included) |
Weight | Approx. 330g |
Attachments | |
Driver for rotary DIP switch setting | 1 |
---|---|
Operation manual | 1 |
Optional accessories
Model | |
C110 | Setting remote console unit, 4 keys, Cable length 0.5m |
---|---|
C120 | Setting remote console unit, 12 keys, Cable length 0.5m |
C120(left)/C110(right)
Download
Product catalogue(PDF)
|
F158 Product catalogue Dowmload | |
---|---|---|
Operation manual(PDF)
|
||
External dimention
|
DXF
(ZIP) |
|
PDF
|
||
Support tools
|
||
Software
|
- User registration is required to download operation manuals, external dimentions, support tools and software .
- Acrobat Reader software from Adobe Systems is required to view PDF files.