F701+
Functionally improved weighing indicator
Product outline
F701+ has outstanding abilities such as High-accuracy amplifier, high sampling rate & High-performance filter which is resistant to vibration.
Furthermore, various functions of Equivalent calibration, Sequential control, Set value restoration and Recovery from power failure are available.
F701+ is an ideal weighing indicator which considering performance and convenience.
F701+ product movie
High sampling rate & resolution
High-Speed A/D conversion and powerful digital processing capability of 500 times/sec.
High resolution of 1/10000 in all input range.
* It can be changed to 100times/sec.
Measurement can be performed quickly and precisely due to high speed A/D conversion.
Auto filter adjustment
Capable of adjusting filter automatically according to an operating condition. Helpful for setting at the test operation.
Equivalent calibration
Equivalent calibration can be made easily by just inputting rated capacity and output of loadcell to F701+ with key button.
Recovery form temporary stop / power failure
Temporary measurement stop, and Operation restart mode are available. Measurement can be performed continuously from the middle .
Set value restoration
Set value can be restored, in case set value is changed by mistake.
Various functions are available
-
Digital low pass filte
As it is resistant to vibration, measurement can be performed quickly and precisely.
*Conventional analog filter is also selectable
-
Sink type / source type are available
Type of I/O signal are selectable form Sink and Source.
-
Displaying accumulated value with one-touch
Accumulated value can be shown with one-touch
-
Connecting with printer by using RS-232C communication
Time data can be output for efficient data management.
-
Various optional interface
D/A converter, BCD output, RS-232C, RS485(Selectable from Modbus-RTU and UNI format), PROFIBUS-DP are available.
I/O board can be easily replaced on site
Specifications
Analog section|Filter|Display section|Setting section|External signal|Interface|General performance|Attachments
Analog section | |
Excitation voltage | DC10V±5% Output current: within 120mA Remote sense type (Up to 4 350Ω load cells can be connected in parallel) |
---|---|
Signal input range | -0.5 to 3.0mV/V |
Zero adjustment range | Automatic adjustment by digital processing -0.5 to 2.0mV/V |
Gain adjustment range | Automatic adjustment by digital processing 0.3 to 3.0mV/V |
Min. input sensitivity | 0.3μV/count |
Accuracy | Non-linearity: within 0.01%/FS Zero drift: within 0.2μV/℃ RTI Gain drift: within 15ppm/℃ |
A/D converter | Speed:Selectable from 500 times/sec., 100 times/sec. Resolution: 24bit(binary) |
Min. indicated resolution | 1/10000 |
Secondary calibration | Equivalent calibration Min. indicated resolution during secondary calibration: 1/1000 (room temperature) |
Filter | |
Analog | Low-pass filter Selectable from 2, 4, 6, 8Hz (-12dB/oct.) |
---|---|
Digital | Low-pass filter Selectable from OFF, 1, 1.5, 2, 2.5, 3, 4, 5Hz |
Display section | |
Display unit | Character height 18.5mm Numerical display (7 digits) by fluorescent display tube |
---|---|
Display value | 5 digits, Sign; Minus sign displayed on most significant digit |
Display frequency | Selectable from 3, 6, 13, 25 times/sec. |
Capacity | 5 digits |
Min. scale division | Can be set from 1 to 100 |
Over scale display | LOAD: A/D converter input over, -LOAD: A/D converter input minus over, OFL1: Net weight over, OFL2: Capacity +9 scale division, OFL3: Gross weight over |
Center zero | A true zero point or the center of each value is displayed. |
Unit | Selectable from kg/g/t/lb/N/None |
Status display | SP3/SP2/SP1/LOCK/ZT/ZALM/STAB/TARE/NET/GROSS/ HI LIM/HI/GO/LO/LO LIM/HOLD/NZ/CZ |
Setting section | |
Setting method | Settings are made by operating the membrane keys. Setting by RS-232C interface (option) and RS-485 interface (option) is also possible |
---|---|
Memory of set value | Calibration value and a part of set value: NOV.RAM (nonvolatile RAM) Other set values: F-RAM (nonvolatile RAM) |
Protect of set value | Protect can be set by Lock switch and Lock parameter. |
Setting item | Upper limit, Lower limit, Near zero, Set point 1, Set point 2, Compensation, Over, Under, Final, Comparison inhibit time, Judging time, Complete output time, Compensation feeding time, Number of times for AZ, Number of times for judging, Auto free fall compensation regulation value, Tare setting, Weighing function 1, Weighing function 2, Weighing function 3, Sequence mode, Function key inhibited, Filter, Motion detect, Zero tracking, Setting value LOCK, Balance weight value, Capacity, Min. scale division, Net over, Gross over, DZ regulation value, Function selection, Compensation for gravitational acceleration, Zero calibration, Span calibration, Equivalent calibration, Input selection, Output selection, Moving average filter, Restart setting set point 1, Restart setting set point 2, Restart setting set point 3 |
External signal You can specify whether PNP (Source) type or NPN (Sink) type when order the F701+. |
|
Output signals (12 points) |
NZ, SP1, SP2, SP3, Under, Over, Lower limit, Upper limit, Stable, Output selection 1, Output selection 2, Output selection 3 Output turns ON when transistor is ON. * PNP(source)type: External voltage must be prepared separately by customer. |
---|---|
Input signals (8 points) |
G/N, D/Z, One-touch tare subtraction, Input selection 1, Input selection 2, Input selection 3, Input selection 4, Input selection 5 Contact (relay, switch etc.) or non-contact (transistor, open collector etc.) can be connected. * PNP(source)type: External voltage must be prepared separately by customer. |
Interface 2 optional interface can be added in addition the standard interface. *1(mark): only 1 option is available. *2(mark): only 1 option is available. |
|
SIF | 2-wire type serial interface |
---|---|
232 | RS-232C communication interface (Option)*1 |
485 | RS-485 communication interface (Selectable from Modbus-RTU, UNI format) (Option)*1 |
BCO | BCD parallel data output interface (Option)*2 |
DAC | D/A converter (Option)*2 |
PRF | PROFIBUS interface (Option) *PROFIBUS-DPV0 *2 |
General performance | |
Power supply voltage | AC100 to 240V (+10% -15%) (free power source 50/60Hz) |
---|---|
Inrush current | 1.5A, 1ms AC100V average load condition (cold start at room temperature) 2.5A, 1ms AC200V average load condition (cold start at room temperature) |
Power consumption | 7W typ |
Operating conditions | Operation temperature: -10 to +40℃ Storage temperature: -20 to +85℃ Humidity: 85%RH or less (non-condensing) |
Dimensions | 192(W)×96(H)×160(D) mm (Projections excluded) |
Weight | Approx. 1.5kg |
Attachments | |
AC input cord (Nominal rating 125V) 2m | 1 |
---|---|
Load cell connector | 1 |
Mini-screwdriver | 1 |
57 series 24p connector for external input/output | 1 |
Operation manual | 1 |
BCD output connector ×1 (with BCD output option) | 1 |
D/A converter connector ×1 (with D/A converter option) | 1 |
Option
Model | Interface |
232 | RS-232C communication interface |
---|---|
485 | RS-485 communication interface (Selectable from Modbus-RTU, UNI format) |
BCO | BCD parallel data output interface |
DAC | D/A converter |
PRF | PROFIBUS interface *PROFIBUS-DPV0 |
Optional accessories
Model | Description |
CAAC2P-P2 | AC input cord 2m |
---|---|
CAAC3P-CEE7/7-P1.5 | AC input cord (Voltage resistance: 250V) 1.5m |
CA4131 | (6-wired) cable with JRC connector at one end 3m |
CA4230 | JRC-PRC (6-wired) conversion relay cable 0.3m |
CA4311 | JRC-PRC (6-wired) conversion relay cable (4-wired to 6-wired) (for 520A use) 1m |
CN3P-2P | 3P-2P converter plug for AC input cord |
CN10 | Loadcell connector (JRC connector) |
CN21 | 57 series 36p connector for BCD output |
CN23 | 57 series 24p connector for external input/output |
CN34 | D-Sub 9p connector for RS-232C |
Download
Product catalogue(PDF)
|
F701+ Product catalogue Dowmload | |
---|---|---|
Operation manual(PDF)
|
||
External dimention
|
DXF
(ZIP) |
|
PDF
|
||
Support tools
|
||
Software
|
- User registration is required to download operation manuals, external dimentions, support tools and software.
- Acrobat Reader software from Adobe Systems is required to view PDF files.