LC240
Loadcell converter
Product outline
LC240 is a low-drift loadcell converter designed for loadcells. With a U300DC preamplifier with a proven track record in stability adopted for the head amplifier, it realizes low drift and low noise features. The bridge excitation power supply can be adjusted to 6 different levels besides the large capacity that allows up to 4 loadcells to be driven in parallel. LC240 is capable of loadcell converter that is standard equipped with the calibration function and current output.
Specification
Excitation voltage | 10V DC ±0.5%, Output current: within 120mA……Standard specification (Up to 4 loadcells at 350Ω can be parallel-connectable.) 2.5, 2.9, 4, 5, 6,6V DC ±0.6% (Switching over via DIP switch) Output current: within 60mA |
---|---|
Zero adjustment range | 0 to approx. 2mV/V Coarse adjustment: 16-step rotary switch Fine adjustment: 20 turn trimmer potentiometer |
Gain adjustment range | 0.45mV/V to 3.0mV/V, 0.225mV/V to 1.5mV/V (Range can be changed by selecting an internal switch) Coarse adjustment: 16-step rotary switch Fine adjustment: 20 turn trimmer potentiometer |
Accuracy |
Non-linearity: within 0.01%/FS Zero drift: within 0.25μV/°C RTI Gain drift: within 50ppm/°C Noise: within 0.2μVp-p RTI (1Hz) |
Output signal | Voltage output: 0 to ±10V, Load resistance: 2kΩ or more, Output resistance: 0.2Ω or less Current output: 4 to 20mA, Load resistance: 500Ω or less |
Low-pass filter |
Low-pass filter (-6dB/oct.)……Standard specification Approx. 1Hz/-3dB |
Calibration value | 1mV/V ±0.2%.)……Standard specification |
Power supply voltage | 100V AC ±10%, 50/60Hz |
Power consumption | Approx. 5VA |
Operating conditions | Temperature: Working temperature range -10 to +40°C Humidity: 85% RH or less (non-condensing) |
Dimensions | 44.6(W)×110(H)×185(D) mm (protruding parts not included) |
Weight | Approx. 820g |
Attachments |
AC input cord・・・1 Spare fuse (0.5A)・・・1 Mini-driver・・・1 Crimping terminal・・・11 Operation manual・・・1 |
* Nonstandard specifications can support the following: (Please specify when ordering.)
・Current output: 2 -10 mA, Load resistance: 1kΩ or less
・Filter: 10, 100, 1kHz , other
・Calibration value: 0.5mV/V
Option
Nonstandard specifications are prepared for LC240. Please specify them when ordering.
Configurable parameter | Standard specification | Changeable specification |
Current output | 4 to 20mA Load resistance: 500Ω or less |
2 to 10mA Load resistance: 1kΩ |
---|---|---|
Filter | 1Hz | 10Hz, 100Hz, 1kHz, other |
Calibration value | 1mV/V | 0.5mV/V |
Optional accessories
Model | |
POT03 | Potentiometer for external zero adjustment |
---|
Download
Product catalogue(PDF)
|
LC240 Product catalogue Dowmload | |
---|---|---|
Operation manual(PDF)
|
||
External dimention
|
DXF
(ZIP) |
|
PDF
|
||
Support tools
|
||
Software
|